Battery Benchmark
GNB 550mAh 1S 100C HV

GNB 550mAh 1S 100C HV

Manufacturer claims: 550 mAh · 1S · 100C · 14 g · LiHV

Buy at rotorama.com – €5.29
504 mAh capacity 91.5 %
3.258 V voltage under load (50 % SOC) 16.1 A
36 flight score

Discharge curve

Flight test

Measured values

Capacity 504 mAh
Capacity honesty 91.5 %
Flight score 36
Energy 1.8 Wh
Voltage under load at 50 % SOC 3.258 V
Internal resistance incl. leads 55 mΩ
Losses during the flight 4.7 %
Weight 14 g
Energy density 134.2 Wh/kg
Energy per 1000 CZK 14.0 Wh/1000 Kč
Dimensions 66 × 18 × 6 mm

How to read the values

Flight score — the result of a simulated flight on the discharge rig. Every battery of the class flies the same flight, consuming 84 % of its label capacity. The 0–100 score combines the weakest cell's sag at both punches, the minimum in the punch block, the mean voltage under load, the energy lost during the flight and the temperature rise. A battery the rig cut off during the flight did not finish and has no score (DNF).

Voltage under load at 50 % SOC — the battery voltage under a 30C load at the moment it has delivered half of its capacity – the “mid-flight voltage” the pilot feels on the throttle. It is measured at the main connector including the leads, because a 1S battery has no balance connector. Higher is better: a battery with a higher voltage under load gives the motors more power at the same throttle and holds its thrust longer. LiHV cells sit inherently a little higher than LiPo, so compare only batteries of the same chemistry.

Internal resistance incl. leads — the DC internal resistance from the three-second load step of the 30C run, measured on the main channel – i.e. including the adapter, leads and connector. Lower is better: less resistance means less voltage drop under load and less heating. The figure is comparable only between 1S batteries measured the same way, never with the four-wire values of multi-cell packs.

Losses during the flight — energy turned into heat instead of thrust during the simulated flight, computed with the same balance as the heat losses: the area between the reference curve and the flight curve over the delivered charge. Lower is better.

Energy density — the reference-discharge energy per kilogram of battery mass including leads and connector. Higher is better – on small batteries every gram counts, on a whoop one gram is 5–8 % of the all-up weight. A higher energy density usually goes hand in hand with lower load capability, so read it together with the voltage under load (1S) or the continuous C (multi-cell packs).