Discharge curve
Measured values
| Capacity | 494 mAh |
|---|---|
| Capacity honesty | 89.9 % |
| Energy | 1.8 Wh |
| Voltage under load at 50 % SOC | 3.190 V |
| Internal resistance incl. leads | 54 mΩ |
| Weight | 14 g |
| Energy density | 129.4 Wh/kg |
| Energy per 1000 CZK | 14.7 Wh/1000 Kč |
| Dimensions | 66 × 18 × 6 mm |
How to read the values
Voltage under load at 50 % SOC — the battery voltage under a 30C load at the moment it has delivered half of its capacity – the “mid-flight voltage” the pilot feels on the throttle. It is measured at the main connector including the leads, because a 1S battery has no balance connector. Higher is better: a battery with a higher voltage under load gives the motors more power at the same throttle and holds its thrust longer. LiHV cells sit inherently a little higher than LiPo, so compare only batteries of the same chemistry.
Internal resistance incl. leads — the DC internal resistance from the three-second load step of the 30C run, measured on the main channel – i.e. including the adapter, leads and connector. Lower is better: less resistance means less voltage drop under load and less heating. The figure is comparable only between 1S batteries measured the same way, never with the four-wire values of multi-cell packs.
Energy density — the reference-discharge energy per kilogram of battery mass including leads and connector. Higher is better – on small batteries every gram counts, on a whoop one gram is 5–8 % of the all-up weight. A higher energy density usually goes hand in hand with lower load capability, so read it together with the voltage under load (1S) or the continuous C (multi-cell packs).
Battery Benchmark